Connection Details
Door Control (5 Position Removable Terminal Block)
Relay NO Normally Open
24V 0.3A
C Common
NC Normally Closed
Auxiliary
Power
PWR - 0.3 A (GND)
PWR + 0.3 A (24 V)
Door Station Jack (RJ12 Telephone Jack)
Center Pair (Red & Green) Door Station
Middle Pair (Yellow &
Black)
Dry Contact Input Max 1 kΩ
Outside Pair (Blue &
White)
Dry Contact Output Max 50 mA 30 V
Telephone Jack (RJ12 Telephone Jack)
Center Pair Telephone
FXO Gateway
Phone System Trunk Port
Door Station (6 Position Terminal Block)
CTRL Connect to Door Station Jack of Doorphone
Controller
CTRL IN OUT
SW Dry Contact Input to Door Station (e.g. Door
Contact, Doorbell Switch); Max. 1 kΩ
DATA Dry Contact Output from Door Station (e.g.
Gate Control); Max 50 mA 30 V